SynBBB is a microfluidic device that allows to reconstruct the complexity of the brain in vivo microenvironment by replicating histological sections of brain tissue cells that communicate with endothelial cells across the blood-brain barrier (BBB). Interactions between brain tissue cells and endothelial cells are easily observed in the SynBBB model by biochemical or electrical analysis.
SynBBB is the only permitted in vitro model of BBB:
此外,该型号提供的 IMN2 TEER 选项可让您准确测量电阻,为实时监测紧密接头提供了一种非侵入性方法。
事实上,细胞之间紧密连接(例如血脑屏障)的形成可以通过测量细胞间细胞间隙中电阻的变化来评估。SynVivo 细胞阻抗分析仪与 SynBBB TEER 设备结合使用,可测量电阻抗(电阻)。
To run the SynBBB assay, two kit formats are available:
Starter Kit | Test kits |
10 SynBBB chips (choice of IMN2 Radial, IMN2 Linear, or IMN2 Radial-TEER co-culture chips) Accessories include tubes, clamps, needles, and syringes Pneumatic perfusion device (for perfusing tubes to remove air) Cellular Impedance Analyzer* (Required for SynBBB TEER measurements)*Included in IMN2-TEER Starter Kit only. | 10 SynBBB chips (choice of IMN2 Radial, IMN2 Linear, or IMN2 Radial-TEER co-culture chips) Accessories include tubes, clamps, needles, and syringes Pneumatic perfusion device (for perfusing tubes to remove air) Cellular Impedance Analyzer* (required for SynBBB TEER measurements) |
To order chips only, select "Chips Only" in the kit selection.
Schematic of the equipment used to develop the BBB model. The apical chamber (outer passage) is used to culture blood vessels (endothelial cells), while the basolateral chamber (central chamber) is used to culture brain tissue cells (astrocytes, pericytes, or neurons). The porous structure enables communication between blood vessels and tissue cells. Outer Channel Width (OC), Traveling Width (T), Slit Spacing (SS), Slit Width (WS).
IMN2 radial | IMN2 TEER | IMN2 Linear |
Outer Channel (OC): 200 µm Tissue Chamber (red): 1.8 mm diameter Slit Spacing (S S): 50 µm Slit Width (W S ): 3 µm Travel (T): 50 µm Chip Depth: 100 µm | Outer Channel (OC): 200 µm Tissue Chamber (red): 1.8 mm diameter Slit Spacing (S S): 50 µm Slit Width (W S ): 3 µm Stroke (T): 50 µm Chip Depth: 100 µm with Impedance Capability | Channel width: 200-500-200 µm Tissue chamber (red): 1.8 mm diameter Slit spacing (S S): 50 µm Slit width (W S ): 3 µm Stroke: 50 µm |
DingXu (Suzhou) Microfluidics Technology Co., Ltd. is a high-tech enterprise dedicated to the field of microfluidics. We are committed to providing customers with comprehensive microfluidic solutions, including customized microfluidic chip development, surface modification, microfluidic chip processing equipment, and microfluidic instruments. Our team boasts extensive experience and technical expertise, continuously combining professional knowledge with innovative thinking to deliver high-quality solutions. We consistently prioritize customer-centric values, embrace self-challenges, and pursue excellence. Through professionalism, innovation, and collaboration, we aim to create greater value for our customers and contribute to a brighter future in the field of microfluidics.